whatsapp: 0086-15153112822
Refrigeration Training Equipment

Air Conditioning System Model didactic equipment Refrigeration Trainer Equipment

Item No.: ZM6157
ZM6157 Air Conditioning System Model didactic equipment Refrigeration Trainer Equipment
INQUIRY
Description

ZM6157 Air Conditioning System Model didactic equipment Refrigeration Trainer Equipment
Climatic chamber with latent and sensitive heat source as cooling load1
* Recirculating and outer air operation1
* Optional data acquisition software (.01)1
* Connection options for the use of different automation solutions
Technical Description
Air conditioning technology is a key topic in building services engineering. For this reason air conditioning technology plays an important role during the training of skilled workers and engineers.
The clear trainer  represents a complete air conditioning system with an air duct and a climatic chamber. The main components of the air conditioning system are the air cooler with condensing unit, fan, steam humidifier and air heater. Three motorised ventilation flaps control the air distribution in the air conditioning system. The climatic chamber is equipped with two different heat sources (wet and dry). Temperature and relative humidity are measured at relevant points in the air duct and displayed digitally. For the refrigeration circuit two manometers with integrated temperature scale and a flow meter provide all relevant measurements.It is operated manually. A key feature of the air conditioning system is that it is fully ready for various automation solutions. The user can thus focus on this important topic during a lesson.
The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.
Learning Objectives / Experiments


- air conditioning system and its components
- conditioning room air
- mixing different air flows
- representation in the h-x diagram for humid air
* humidification and dehumidification
* heating and cooling
- representation of the circuit in the log p-h diagram
- effect of a cooling load (dry and wet)
- recirculating and outer air operation 
In conjunction with optional accessories
- automation in an air conditioning system
Specification
[1] model of an air conditioning system with outer air and recirculating operation
[2] air duct with transparent front
[3] air duct with fan, air cooler, humidifier, flaps, air heater and sensors
[4] chamber with wet (latent) and dry (sensitive) heat source as cooling load
[5] motorised flaps for recirculating and outer air operation
[6] process schematic with signal lamps
[7] air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
[8] refrigerant R134a, CFC-free
Technical Data
Air-cooled condensing unit
- power consumption: 140W at -10°C
- refrigeration capacity: 320W at +5/40°C
Humidifier
- heating power: 400W
Air heater
- heating power: 360W
2 heaters in the chamber as cooling load
- power output: 0...250W each, freely adjustable
Flow cross-section of the air duct
- WxH: 155x155mm
Measuring ranges


- temperature: 0...50°C
- humidity: 10...90% r.h.
- power: 0...600W (power consumption of the compressor in the condensing unit); 2x 0...300W (cooling loads)
- pressure (refrigerant): -1...9bar / -1...24bar
- flow rate (refrigerant): 1,5...23,5L/h
- air velocity: 0...2,5m/s
Dimensions and Weight
LxWxH: 2.010x760x1.910mm
Weight: approx. 309kg
Required for Operation
230V, 50/60Hz, 1 phase or 230V, 60Hz, 3 phases
Water connection
Scope of Delivery
1 trainer, filled with refrigerant
1 set of instructional material