whatsapp: 0086-15153112822
Electrical Training Equipment

Didactic Bench Fire Alarm Teaching Education Equipment For School Lab Electrical Engineering Training Equipment

Item No.: ZM5125A
ZM5125A Didactic Bench Fire Alarm Teaching Education Equipment For School Lab Electrical Engineering Training Equipment
INQUIRY
Description

ZM5125A Didactic Bench Fire Alarm Teaching Education Equipment For School Lab Electrical Engineering Training Equipment
I.Training purpose
This experimental training device enables students to do fire alarm system components, function, composition and principles understanding training. 
The experimental training device enables students to do fire and alarm linkage simulating operation, the fire-alarm controller panel indicators and buttons function operation, fire-alarm controller state understanding operation, fire-alarm controller basic functions, time modifying operation, password modifying operation, different passwords permissions operation, communication management operation, the machine self-test operation, print management operation, system initialization operation, the total number querying operation, the machine information operating, event recording and querying operation, fire alarm records querying operation, equipment start-stop operating, loop editing by group , single-point loop editing, shielding open operation, automatic login operation, linkage programming operation, sound and light linkage setting operation, networking with CRT fire monitoring center operation, networking with fire radio telephone system experimental training device operation, networking with automatic sprinkler extingiushment system experimental training device operation, component structure identifying and installing, connect the various parts according to the circuit diagram, design and install a simple application system .
The experimental training device enables students to judge and deal with line faults, judge and correct programming setting error.
2. Technical specification 
Working voltage: single phase three wire 220V±5%50Hz 
Whole machine capacity: <200W 
Boundary dimension: 150×70×180cm3 
Safety protection: it is equipped with electric leakage automatic protection device and ground protection. 
Fault setting:  fault setting module can carry out controller setting and the fault setting and shooting of hardware circuit. 


3.Training project 
Training one: the understanding training of Fire Detection Linked System component , function, content and principle 
Training two: fire and alarm linked simulation operation training 
Training three:the operation training of indicator light and button function on the fire control mainframe board 
Training four: the understanding operation training of fire control mainframe state. 
Training five: fire control mainframe basic function operation training 
Training six: modification time operation training 
Training seven: modification password operation training 
Training eight: the training operation of different password jurisdiction
Training nine: communication management operation training 
Training ten: local machine self-inspection operation training 
Training eleven: the operation training of print management
Training twelve: the operation training of system initialization
Training thirteen: total number inquire operation training 
Training fourteen: local machine information operation training 
Training fifteen: incident record inquire operation training 
Training sixteen: fire alarm record inquire operation training 
Training seventeen : machine start and stop operation training 
Training eighteen: editing operation training according to group circuit


Training nineteen: single point circuit editing operation training 
Training twenty: shield opening operation training 
Training twenty-one: automatic login operation training 
Training twenty-two: linked editing operation training 
Training twenty-three: acousto-optic linked setting operation training 
Training twenty-four: the networking operation training of CRT fire control monitoring center.
Training twenty-five: the networking operation training of fire control broadcast phone system experiment device. 
Training twenty-six: the networking operation training of automatic sprinkler fire extinguishing system experiment device 
Training twenty-seven: the structure understanding and installation training of component 
Training twenty-eight: he judgment and treatment operation training of wiring fault 
Training twenty-nine: the judgment and rectification training of programme setting error
Training thirty-: each portion wiring training according to circuit diagram 
Training thirty-one : design and install a simple application system