General Cycle Air Conditioning Trainer Refrigeration Training Equipment
Item No.: ZM6305
ZM6305 General Cycle Air Conditioning Trainer with Reverse Cycle with Hermetic Compressor
1. Product introduction
This training device is used for in-depth study of ordinary refrigeration compression cycles. The condenser and evaporator have adjustable
ZM6305 General Cycle Air Conditioning Trainer with Reverse Cycle withHermetic Compressor Educational Equipment 1. Product introduction
This training device is used for in-depth study of ordinary refrigeration compression cycles. The condenser and evaporator have adjustable speed fans, which can intuitively reflect the refrigeration changes of the refrigerant under 4 different throttling devices under the same working conditions, and change the heat transfer effect of the condenser and evaporator through the fan speed adjustment. , Refrigeration change of refrigerant under different working conditions. Applicable to the teaching and training of skills appraisal, assessment work, refrigeration technology in higher vocational colleges, vocational schools, principles and maintenance of household refrigeration equipment, and maintenance of refrigeration equipment.
2. Device Features
(1) The training device system loop contains expansion valves and capillary throttling devices. The capillaries are divided into three different lengths. The system can intuitively show the impact of different throttling devices on the cooling effect when the system is running.
(2) Adjustable speed fans for condensers and evaporators in refrigeration systems.
(3) The refrigerating cycle pipeline is laid on the equipment installation board. The high and low temperature areas are painted with different colors for easy observation and differentiation. At the same time, a refrigerant-specific flow meter is used to observe the refrigerant flow in real time.
(4) The overall structure of the aluminum profile frame is adopted, and the pillars are 125 * 35mm special industrial aluminum profiles customized for mold opening. The surface is imported from the Netherlands ACZU powder spray treatment. 4 universal wheels are installed for easy movement.
(5) The equipment has a good safety protection system. High and low pressure protection switches are installed in the refrigeration cycle. When the system pressure is abnormal, the compressor can be stopped immediately to protect the compressor and the system. The electrical circuit is equipped with a leakage protection switch, emergency stop button and reliable ground protection measures to ensure that Equipment and personal safety.
3. Technical Parameters
(1) Input power: single-phase three-wire ~ 220V ± 10% 50Hz
(2) Device capacity: <0.4kVA
(2) Overall dimensions: 1600mm × 800mm × 1800mm
(3) Weight: <100kg
(4) Working conditions: ambient temperature 10 ℃ ~ 30 ℃ relative humidity < 75% (25 ℃)
(5) Refrigerant type: R134a
3. basic component
(1) Training platform frame: adopts the overall structure of aluminum profile frame, the columns are 125 * 35mm special industrial aluminum profiles customized for mold opening, and the surface is treated with imported Dutch ACZU powder spray coating, which is sturdy and beautiful (samples with band only)
(2) Compressor unit: adopts 1 / 2P compressor, with overheating and overcurrent protection. The compressor is fixed on the desktop, and the working state of the compressor can be observed visually.
(3) Condenser and evaporator: with adjustable speed fan.
(4) Reservoir and gas-liquid separator unit: connected in the refrigeration cycle pipeline.
(5) Experimental screen: installed with refrigeration circuit components, including dry filter, sight glass, hand valve, refrigeration pipeline, high and low pressure gauge, high and low pressure controller, expansion valve and other components.
(6) Temperature meter, which measures the real-time temperature of the compressor exhaust outlet temperature, condenser outlet temperature, evaporator inlet temperature, compressor inlet temperature, ambient temperature and other locations. The temperature measurement probe can be changed to the measurement position according to the measurement needs.
(7) Multi-function meter: real-time display of voltage, current, power factor and other data of the system, which can carry out 485 communication.
(8) Flow meter: The refrigerant high pressure flow meter is used to observe the real-time flow rate of the refrigerant.
4. Can complete the training project
(1) Refrigeration training with expansion valve
(2) Refrigeration training with standard capillary
(3) Capillary training for too short time
(4) Refrigeration training when the capillary is too long
(5) Refrigeration training of different throttling devices under the same working condition
(6) Refrigeration training of the same throttling device under different working conditions
(7) Liquefaction process of refrigerant in condenser
(8) Gasification process of refrigerant in evaporator
(9) The role of the accumulator in the refrigeration system
(10) The role of gas-liquid separators in refrigeration systems