ZMR006 Training Equipment on VRV or VRF Systems Vocational Education Equipment Didactic Equipment Refrigeration Trainer
1. Product Introduction
1.1 Product Description
The residential central air conditioning training and assessment device is suitable for practical training in refrigeration technology, refrigeration fluid machinery, household refrigeration equipment principles and maintenance, refrigeration and freezing technology, and refrigeration equipment maintenance (elementary, intermediate, and advanced) at vocational colleges and universities. It cultivates skilled, applied professionals who master the theoretical knowledge and practical skills of air conditioning and refrigeration technology and are capable of engaging in the technical upgrades, retrofit design, installation and commissioning, maintenance, inspection, and technical management of air conditioning and refrigeration equipment and systems.
1.2 Product Features
1. The system utilizes a one-to-nine unit equipped with nine different types of indoor units, providing students with a comprehensive understanding of central air conditioning. The variable-frequency compressor has an adjustable range of 48% to 104% of its rated capacity. Energy regulation must take into account the time required for compressor frequency adjustment. Due to the dynamic characteristics of variable-frequency compressors, energy consumption must be below a certain speed during adjustment. Therefore, adjustment is performed step by step. The compressor motor speed varies proportionally to the indoor air conditioning load. 2. Diverse System Terminal Processors: Nine different terminal processor types, including ceiling-mounted (embedded), wall-mounted, and fan-coil units, are used to help students understand the diverse structural forms of indoor units.
Each terminal processor is equipped with a cooling system flow plate, a control circuit flow plate, a temperature gauge, and a pressure gauge, allowing visibility into all control circuits within the unit.
3. System Integrity and Independence: The control, protection, and display functions are identical to those of actual residential central air conditioners, allowing each user terminal to be independently controlled under the same operating conditions.
The control console is ready for operation with a 380V AC power supply, occupying a small footprint, saving space and reducing capital investment.
4. The device intuitively demonstrates the system structure and operating principles of residential central air conditioners, facilitating demonstrations for teachers and students' understanding and mastery of textbook knowledge. Rational Structure and Attractive Design: The device boasts a compact and attractive design, and is equipped with universal wheels and a fixed adjustment mechanism for easy movement and fixation.
The training system features a simulated fault setting function, allowing for faults in both the cooling and electrical systems. By using concrete phenomena, students' analytical skills are enhanced, linking theory with practice, and cultivating practical skills.
5. Equipped with a current-type leakage protection device. When the ground leakage current exceeds a certain value, the circuit breaker trips and cuts off the power supply. A thermal protection device is also provided to prevent the compressor from overheating and overloading.
2. Technical Specifications
2.1 Basic Technical Parameters
Working power supply Three-phase five-wire 380V±10% 50Hz
Refrigerant parameters R410a
2.2 Equipment Parameters
Dimension 3400mm×1100mm×2100mm
Weight ≤400kg
3.Product Introduction
3.1Product Overview
No. Name Quantity
1 Main panel module 1
2 Thin duct indoor unit module 1
3 Four-way indoor unit module 1
4 Kitchen indoor unit module 1
5 Two-way indoor unit module 1
6 One-way indoor unit module 1
7 Concealed indoor unit module 1
8 Fresh air indoor unit module 1
9 On-hook unit module 1
10 Low net pressure air indoor unit module 1
11 Air conditioner outdoor unit 1
12 Concealed indoor unit 1
No. Name Quantity
1 Transparent hose 1
2 High and low pressure gauges 1
3 High-pressure line (red) 1
4 Transmission line (yellow) 1
5 Low-pressure line (blue) 1
6 4mm electrical safety connection cable (blue, 2m) 15
7 4mm electrical safety connection cable (blue, 1.5m) 15
8 3mm electrical safety connection cable (black, 1.5m) 15
9 USB drive 1
10 Hex wrench 1
11 Oil bottle 1
12 Rotary vane vacuum pump 1
13 Adjustable wrench 2
14 4mm electrical safety connection cable (red, 1.5m) 15
15 3mm electrical safety connection cable (red, 1.5m) 15
16 Portable thermometer 1
17 Portable thermometer probe 1
18 Hose clamp 4
19 Communication cable 1
20 Hook-up remote control 1
21 4mm electrical safety connection cable (red, 2m) 15
3.3 Indoor Unit Module Introduction
Main Panel
No. Name
1 HMI
2 Error code explanation table
3 Three-phase power indicator light
4 4P circuit breaker
5 Multi-function three-phase meter
6 Communication unit
7 AC220V output unit
8 Outlet
Thin duct indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Four directional indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Kitchen indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Two directional indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit

One Directional Indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Floor Hidden indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Fresh air indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
Hang-up module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
10 Hang up
Low net pressure air duct indoor unit module
No. Name
1 Schematic diagram
2 Schematic diagram symbol explanation
3 Display controller
4 Voltmeter
5 Amperemeter
6 Return air vent
7 Air outlet
8 Power supply unit
9 Communication unit
10 On-hook unit
4. Product Teaching Experiment List
(1) Single-direction fault setting experiment
(2) Fan fault setting experiment
(3) Hook-up fault experiment
(4) Two-way fault setting experiment
(5) Four-direction indoor unit fault setting experiment
(6) Kitchen indoor unit communication fault experiment
(7) Outdoor unit high pressure fault experiment
(8) Outdoor unit four-way reversing valve fault setting experiment
(9) Low-pressure fault setting experiment
(10) Display controller fault experiment
(11) Fresh air fault setting experiment
(12) Hidden indoor unit fault experiment
(13) Freon Pipe Connection and Charging Experiment
(14) Fluorine recovery operation method experiment
(15) Vacuum pump operation experiment
(16) Fluorine recovery standard judgment experiment
(17) Software connection and remote control experiment