whatsapp: 0086-15153112822
Refrigeration Training Equipment

TRAINING SIMULATOR FOR FAILURE OF REFRIGERATION SYSTEMS educational Air Conditioner Trainer Equipment

Item No.: ZM6315
ZM6315 TRAINING SIMULATOR FOR FAILURE OF REFRIGERATION SYSTEMS educational Air Conditioner Trainer Equipment
INQUIRY
Description

ZM6315 TRAINING SIMULATOR FOR FAILURE OF REFRIGERATION SYSTEMS educational Air Conditioner Trainer Equipment
Demonstration of a multi-evaporator system operating at various temperatures
Includes 25 typical purlins each operated by a push button
Allows you to do practical work for detecting and locating faults
Familiarization of students with three-phase networks.
General description
The 811 fault simulation training bench is a fully operational refrigeration system equipped with two visible evaporators simulating a positive and negative cold room, operating from a single semi-hermetic compressor-condenser group.
The bench is fully fabricated from standard commercial components, including all primary and safety controls, and will provide students with hands-on experience in adjusting and troubleshooting a three-phase multi-evaporator refrigeration system.
A combination of 25 different faults on the refrigeration circuit and the electrical circuit
can be simulated by the trainer, allowing students to study both normal and abnormal operating conditions. The purlins that can be created are
Fault in the compressor valve
Anomaly of the oil separator
Overload
     Under charge
Leakage of the non-return valve
Anomaly of the evaporator pressure regulator
Thermostatic expansion valve not working - evaporator freezer
Anomaly of the thermostatic expansion valve - freezer evaporator


Thermostatic expansion valve not working - evaporator cold room for refrigeration
Anomaly of the thermostatic expansion valve - evaporator cold room freezing
Evaporator suction line of the positive cold room - frosted
Evaporator suction line of the positive cold room - frosted
Restriction of the filter drier
Discharge pressure anomaly
Malfunction of the hot gas defrosting system
Suction pressure too low - decreasing the capacity of the evaporator
Suction pressure too high
Anomaly on one phase
Anomaly on two phases
One set of branch contacts (motor overload protection)
Two sets of branch contacts (motor overload protection)
Thermal overload protection of the motor switch box
Coil fault - motor protection - starter box
Thermostatic anomaly - freezing chamber - does not work
Thermostatic anomaly - refrigeration chamber - does not work
The 811 training bench is one of a range of training devices designed to provide hands-on training in the areas of Refrigeration and Air Conditioning. Each teaching material has been carefully designed to provide training in specific areas that students must study in most courses on Refrigeration and Air Conditioning.
 On the bench 811, all the standard elements are visible, mounted on a steel frame with stainless steel panels. ^ instrumentation includes; measurement of condensing, evaporation and suction pressures, mechanical and digital temperature measurement, a digital multimeter, The system
includes a reversible gas defrosting system, an anti-liquid blow bottle, an oil separator, variable speed fans for the evaporator and the condenser. Faults generated by the trainer are caused by integrated components that are hidden from students.
Specific features
Dimensions and weight: approx 2160 x 700 x 1700 mm - 425 kg
The device is mounted on a frame with casters with a base and a rear panel in stainless steel.
One compressor: Semi-hermetic, 0.37 kW. 1450 RPM
A Condenser: Air-cooled, aluminum fins, copper coil.
Evaporators: display evaporators. Aluminum fins, copper coils with hot gas defrost
Two thermostatic expansion valves
Liquid tank


Control equipment: Adjustment of high and low pressure, thermostatic control, control of evaporator pressure, adjustment of cooling capacity, adjustment of condensing pressure and crankcase pressure, Low and high pressure switches.
Instrumentation
- Digital temperature indicator with 10 measurement channels -4 manometers (3 vacuum gauges, 1 high pressure)
- 2 dial thermometers
- Portable digital multimeter
Refrigerant: R134a.
25 switches located on the side of the panel under a cover mounted on hinges allow the trainer to generate the various failures.
An electrical control unit is mounted on the panel and includes easily accessible three-phase relays, fuses and an overload protector. An integrated three-phase residual current device protects against earth leakage. The fan speed control and the defrost switch with its indicator are also mounted on the panel.
User manual with practical work Services required:
Space required: A floor area of 2.5 mx 1 m
Electricity: a 380-440V power supply - 50 Hz - three phase