SR3014 Ventilation system Thermal Training Equipment Heat Transfer Lab Equipment For College, University Brand: ShouldShine Model:SR3014 Learning Objectives / Experiments - design and operation of a ventilation system - pressure measurements in the air duct - determine the electric drive power of the fan - determine the flow rate - design and operation of components such as * protective grating * multi-leaf damper * filter * heat exchanger as air heater/cooler * fan * inspection cover * sound insulation link * ventilation grill with adjustable flow rate * fire protection flap
* ceiling vents Specification [1] operation of a ventilation system [2] all components from ventilation technology, some with sight windows [3] protective grating and adjustable multi-leaf damper at the air inlet [4] filter for air purification [5] heat exchanger to heat/cool the air [6] belt-driven radial fan [7] 2 sound insulation links [8] various air outlets for air distribution in the room: disc valve, ceiling vent and ventilation grill with adjustable flow rate [9] inspection cover for inspection purposes [10] fire protection flap prevents the cross-over of fire and smoke in the air duct [11] air duct with pressure measurement connections [12] pressure measurements with inclined tube manometer [13] current measurement to determine the power consumption of the fan [14] determine the flow rate via differential pressure
Technical Data Air duct: 1845x630x305mm Fan - max. flow rate: 2500m³/h - speed: 1600min-1 - drive motor: 750W Air-to-water heat exchanger as air heater/cooler - capacity: 7,6kW Measuring ranges - pressure: 0...700Pa - current: 0...4A Dimensions and Weight LxWxH: 1960x900x2000mm Weight: approx. 263kg Required for Operation 400V, 50/60Hz, 3 phases or 230V, 60Hz, 3 phases Water connection (hot and cold), drain